Fire safety reports and fire protection projects

From the protection concept to approval and implementation: complete fire safety reports, coordinated with the building design and prepared by our design office, with qualified in-house engineers and designers authorised by the Emergency Management Agency.

Company
TEKNIKU GROUP SH.P.K.Trading name: TEKNIKU SAFETY · Business no.: 812293984
Designer authorisations
AME nr. 164/02 · 165/02Fire safety reports; design of detection, alarm and suppression systems
Design office
In-house engineersA qualified design team; every document is checked by a second engineer
Fire safety reports

The written part, calculations and drawings.

System design

Detection, alarm, hydrants, suppression, smoke.

Evacuation plans

For every floor, to ISO 23601.

Through to approval

Submission, clarifications and technical acceptance.

01

When is a fire safety report required?

A fire safety report is the technical document that sets out the measures needed to prevent fire, limit its spread, evacuate people safely and allow the fire service to intervene effectively. It is required in the following cases:

01

Building permit

For new buildings, as required by the municipality and AME.

02

Renovation or extension

When the layout, escape routes or fire load change.

03

Change of use

E.g. from warehouse to commercial building, from office to hotel.

04

Technical acceptance

When proof that fire protection measures have been implemented is required.

05

AME inspections

To address findings and bring the existing situation into line.

06

Insurer and investor requirements

Independent technical assessments and reports.

Types of building

  • Residential and multi-occupancy buildings
  • Commercial buildings and offices
  • Hotels, restaurants, shopping centres
  • Hospitals, schools, public buildings
  • Factories, workshops and warehouses
  • High-rise buildings (over 22 m)
  • Rooftop and ground-mounted photovoltaic (PV) systems
  • Fuel stations and higher-risk buildings

Every report is prepared for the specific building: the classification, fire load and protection measures are set by its use, height, floor area and number of occupants.

02

What the report contains

The content follows Administrative Instruction (MIA) No. 12/2017 on the content of fire safety reports. The report consists of a written part with calculations and a set of drawings, and its structure is adapted to the type and complexity of the building.

Part 1 · Written part and calculations

  1. 01Details of the building, investor and designers
  2. 02Legal basis and applicable standards
  3. 03Classification of the building by use, height and risk
  4. 04Calculation of the specific fire load
  5. 05Fire compartments and fire resistance of building elements (EN 13501-2)
  6. 06Reaction to fire of materials (EN 13501-1)
  7. 07Escape routes: length, width and capacity
  8. 08Emergency lighting and safety signs (EN 1838, EN ISO 7010)
  9. 09Fire detection and alarm system (EN 54)
  10. 10Hydrant network and water supply (EN 671, EN 14384)
  11. 11Calculation and placement of fire extinguishers (EN 3-7)
  12. 12Automatic suppression: sprinklers (EN 12845), gas, kitchens
  13. 13Smoke and heat exhaust (EN 12101)
  14. 14Electrical installations, lightning protection (EN 62305) and PV systems
  15. 15Access and hardstanding for fire appliances
  16. 16Organisational measures, maintenance and training
  17. 17Equipment specification and cost estimate (BOQ)

Part 2 · Drawings

  1. 01Site plan with fire service access and outdoor hydrants
  2. 02Floor plans with fire compartments and protection measures
  3. 03Escape routes, exits and emergency lighting
  4. 04System diagrams: detection, alarm, hydrants, suppression
  5. 05Evacuation and rescue plans (ISO 23601)
Delivery format

The signed and stamped report in print and electronic form (PDF), with drawings in DWG/PDF. On request, coordination reports are also prepared in English.

03

How we work

  1. 1
    Request and documents

    We receive the architectural design and building data and define the purpose of the report.

  2. 2
    Site visit

    For existing buildings: assessment of the condition, escape routes and existing systems.

  3. 3
    Protection concept

    Classification, fire compartments and required systems, coordinated with the architect and building services designers.

  4. 4
    Preparing the report

    The written part, calculations and drawings, in line with the applicable legislation and standards.

  5. 5
    Internal check

    Quality control and a check by a second engineer before signing.

  6. 6
    Submission and approval

    Submission to the municipality or AME, with clarifications and additions through to approval.

  7. 7
    Support during construction

    Consultation during construction, checking that measures are implemented, and support for technical acceptance.

Documents we need

  • Architectural design (plans, sections, elevations) in DWG or PDF
  • Use of the building and expected number of occupants
  • Building permit or existing documentation (if any)
  • Electrical and mechanical services designs (if they exist)
  • Contact details of the investor and lead designer
Timescale

Set by the size and complexity of the building and confirmed in the quote, once the complete documentation has been received.

04

Additional services

System design

Fire detection and alarm systems, hydrant networks, sprinklers, gas suppression and commercial kitchen systems.

Evacuation plans

Evacuation and rescue plans for every floor, ready to put up.

Project review

Independent assessment of existing reports and projects, with proposals for improvement.

Coordination reports

Integration and coordination reports with other designers, also in English for international investors.

Construction supervision

Checking measures on site and preparing for technical acceptance.

Photovoltaic systems

Dedicated reports for PV systems: fire service access, array separation and safe shutdown.

Why TEKNIKU SAFETY?

  • Our own design office, with qualified engineers employed in-house
  • Designers authorised by AME for fire safety reports and for detection, alarm and suppression systems
  • Every document is double-checked before submission
  • Knowledge of Kosovo legislation and European EN standards
  • Experience with commercial, industrial and public buildings and PV systems
  • Direct coordination with the architect and building services designers
  • Complete solutions from design to equipment and maintenance, together with TEKNIKU SH.P.K.
Part of the TEKNIKU group

Once the report is approved, TEKNIKU SH.P.K. provides equipment supply and installation, fire extinguisher servicing, hydrant network testing, lightning protection measurements and staff training – from a single partner.

05

Legal basis and standards

Reports are prepared in line with the legislation in force in the Republic of Kosovo and, where local legislation does not cover an area, to harmonised European standards.

Kosovo legislation

Law No. 08/L-261
On fire protection
Law No. 04/L-110
On construction
AI (MIA) No. 12/2017
On the content of fire safety reports
AI (MIA) No. 04/2018
Administrative Instruction of the Ministry of Internal Affairs
Regulation No. 24/2012
Including the classification of high-rise buildings (over 22 m)
Other AME secondary legislation
Requirements for evacuation plans and organisational measures

European standards

EN 13501-1 / -2
Reaction-to-fire and fire-resistance classification
EN 54
Fire detection and alarm systems
EN 12845
Automatic sprinkler systems
EN 671 · EN 14384
Indoor and outdoor hydrants
EN 3-7 · EN 1866-1
Fire extinguishers
EN 12101
Smoke and heat control
EN 1838 · EN 50172
Emergency lighting
EN ISO 7010 · ISO 23601
Safety signs and evacuation plans
EN 62305
Lightning protection

Request a quote for your fire safety report

Send us the architectural design and building details – the quote is free of charge.

Request a quote →